NOTE: Standard operating temperature range is -20 to 400°F (-28 to 204°C). For applications requiring higher temperatures, select the -HT option shown on page BV-2.
*CAUTION: The maxiumum allowable working pressure (MAWP) of the valve shall not exceed the MAWP of the valve series or the selected connection, whichever is less.
Model No.
| Maximum Pressure*
| Port | Cv | Page | |||
3-way Valves for Switching Service
| 3K34 | 3,000 psi
| 210 bar
| 0.250"
| (6.4 mm)
| 1.00
| BV-21
|
3K63 | 6,000 psi
| 410 bar
| 0.187"
| (4.7 mm)
| 0.56
| BV-22
| |
3K93 | 10,000 psi
| 690 bar
| 0.187"
| (4.7 mm)
| 0.56
| BV-24
| |
3K106 | 10,000 psi
| 690 bar
| 0.375"
| (9.5 mm)
| 2.40
| BV-26
| |
3KOS108
| 10,000 psi
| 690 bar
| 0.500"
| (12.7 mm)
| 5.00
| BV-28
| |
3K123 | 12,000 psi
| 830 bar
| 0.187"
| (4.7 mm)
| 0.56
| BV-30
| |
3K203 | 20,000 psi
| 1380 bar
| 0.187"
| (4.7 mm)
| 0.56
| BV-32
| |
3K206 | 20,000 psi
| 1380 bar
| 0.375"
| (9.5 mm)
| 2.40
| BV-34
|
3-way Valves for Diverting Service
| 3DVK34
| 3,000 psi
| 210 bar
| 0.250"
| (6.4 mm)
| 1.00 | BV-21
|
3DVK63
| 6,000 psi
| 410 bar
| 0.187"
| (4.7 mm)
| 0.56 | BV-22
| |
3DVK93 | 10,000 psi
| 690 bar
| 0.187"
| (4.7 mm)
| 0.56 | BV-24
| |
3DVK106 | 10,000 psi
| 690 bar
| 0.375"
| (9.5 mm)
| 2.40
| BV-26
| |
3DVKOS108
| 10,000 psi
| 690 bar
| 0.500"
| (12.7 mm)
| 5.00
| BV-28
| |
3DVK123
| 12,000 psi
| 830 bar
| 0.187"
| (4.7 mm)
| 0.56 | BV-30
| |
3DVK203 | 20,000 psi
| 1380 bar
| 0.187"
| (4.7 mm)
| 0.56 | BV-32
| |
3DVK206
| 20,000 psi
| 1380 bar
| 0.375"
| (9.5 mm)
| 2.40
| BV-34
|